CE FFP2V Dolomite Light Cup Respirator, Dolomite Dust Mask , Filtering Face-Piece Respirator
1 . Descriptions :
FFP2V D mask is in compliance with dolomite dust clogging test, it is fully metal free, light and comfortable. The innovative SELF-SET technology allows self adjustment on the face without the help of the internal and external nosepiece. The elastic bands slide along the mask to hang up the respirator around the neck when the mask is not used. Structure and materials are long lasting and avoid the collapse in humid environments.
2. Knowledage Corner
- dusts: little solid particles suspended in the air deriving from the crushing of solid material. Example: milling, grinding, smoothing and abrasive processes;
- smokes: very little solid particles deriving from vaporizing process and then condensation in solid material due to high heat. Example: foundry, welding and flame cutting processes;
- mists: little droplets of liquid materials deriving from atomization process of liquid materials. Example: plating, blending or production of metal dust;
- gases: substances similar to air in terms of diffusion in the environment. Gases such as carbon monoxide; carbon dioxide; nitrogen and helium;
- vapours: it is the gaseous state of substances that are solid or liquid in nature, so they generate from the evaporation of solids and liquids. Petroleum, for example, is liquid but it evaporates easily producing vapour; diluents and solvents produce vapours, too.
3 . Certification
CE Standard for Disposable Respirators |
EN: 149:2001 + A1:2009 |
Distinguish | Filter Efficiency | Penetration | Resistant |
FFP1 NR | ≧80% | < 20% | < 21mmH2O |
FFP2 NR | ≧94% | < 5% | < 24mmH2O |
FFP3 NR | ≧99% | < 1% | < 30mmH2O |
This product has been tested according to the following European Standard:
- EN149: 2001 +A1: 2009. Respiratory protective devices. Filtering half masks to protect against particles. Requirements, testing, marking.It complies with European Regulation (EU) 2016/425 on Personal Protective Equipment (PPE).Category III.EU type examination certificate (module B) issued by BSI , notified body n°0086.
- The PPE is subject to the conformity assessment procedure based on internal production control plus supervised product checks at random intervals set out in Annex VII under surveillance of BSI , notified body n°0086.
4 . Expiry date and packing
- If maintained as per storage instructions, product can be used up to 5 years from date of manufactory.
- The package of this cup mask with valve is 20pcs/box , 20box/carton and the size of the carton is 64.5*54*27cm.